| Product |
|
|  | | | Contact now | | | |
|
| Application: It can be connect to various inductive load and resistant load in good working performance without limitation.
Specification scope: The allowable input voltage change scope is 160V-275V with efficiency of 85%.
Standby time: Power supply operating time can enlarge batteries. |
| |
|
|  | | | Contact now | | | |
|
| Application: exclusive use for UPS of communication PHS system.
Specification scope: 120W
Standby time: X525-4: 6-8 hours; X525-8: 12-16 hours. |
| |
|
|  | | | Contact now | | | |
|
| Application: it is applicable to illumination system of road, bridge, culvert, square, speedway and supermarket and can save electricity as high as 30%-40%. |
| |
|
|  | | | Contact now | | | |
|
| Adopting advanced sing energy distributing technology, the main circuit is constructed by paralleling the sing energy distributor and the high power filter. When the output voltage is changed because of the undulation of the supply voltage or the load, these products control the SCR element angles through sampling circuit, and comparing and triggering unit to change the current which leads to the… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:30KVA
INPUT VOLTAGE RANGE:380VAC
INPUT FREQUENCY RANGE:50/60HZ±5%
INPUT PHASE:THREE PHASES
OUTPUT VOLTAGE RANGE:220VAC
OUTPUT FREQUENCY RANGE:50/60HZ
OUTPUT VOLTAGE STABILIZED DEGREE:±1%
OUTPUT WAVEFORM:SINE WAVE
OUTPUT CAPACITY FACTOR:1-0.8
OUTPUT DISTORTION:<3%(LIEAR LOAD)
INSTANT RESPONSE:MAX. VOLTAGE VARIES WITHIN 4%(100%)LOAD INPUT OR TRANSFER
BATTERY SYSTEM VOLT… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:20KVA
INPUT VOLTAGE RANGE:380VAC
INPUT FREQUENCY RANGE:50/60HZ±5%
INPUT PHASE:THREE PHASES
OUTPUT VOLTAGE RANGE:220VAC
OUTPUT FREQUENCY RANGE:50/60HZ
OUTPUT VOLTAGE STABILIZED DEGREE:±1%
OUTPUT WAVEFORM:SINE WAVE
OUTPUT CAPACITY FACTOR:1-0.8
OUTPUT DISTORTION:&lt;3%(LIEAR LOAD)
INSTANT RESPONSE:MAX. VOLTAGE VARIES WITHIN 4%(100%)LOAD INPUT OR TRANSFER
BATTERY SYSTEM … |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:15KVA
INPUT VOLTAGE RANGE:380VAC
INPUT FREQUENCY RANGE:50/60HZ±5%
INPUT PHASE:THREE PHASES
OUTPUT VOLTAGE RANGE:220VAC
OUTPUT FREQUENCY RANGE:50/60HZ
OUTPUT VOLTAGE STABILIZED DEGREE:±1%
OUTPUT WAVEFORM:SINE WAVE
OUTPUT CAPACITY FACTOR:1-0.8
OUTPUT DISTORTION:<3%(LIEAR LOAD)
INSTANT RESPONSE:MAX. VOLTAGE VARIES WITHIN 4%(100%)LOAD INPUT OR TRANSFER
BATTERY SYSTEM VOLTAGE:… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:8KW
INPUT VOLTAGE:1 PHASE 220VAC±25% 3 phase:380VAC±25%
INPUT FREQUENCY:50 OR 60HZ±5%
output voltage:220VAC±5% ADJUSTIBLE
OUTPUT FREQUENCY:50HZ±0.5% FREE RUNNING
VOLTAGE REGULATION:±1%
transfer response:±4% 100% load
waveform : sine wave &lt;3% 0-100% LINEAR LOAD
OVERLOAD CAPACITY:120-150% FOR 30s,&gt;150% AUTO.LEAP TO BYPASS
POWER FACTOR:0.8-1,LAG
CR… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:6.4KWKW
INPUT VOLTAGE:1 PHASE 220VAC±25% 3 phase:380VAC±25%
INPUT FREQUENCY:50 OR 60HZ±5%
output voltage:220VAC±5% ADJUSTIBLE
OUTPUT FREQUENCY:50HZ±0.5% FREE RUNNING
VOLTAGE REGULATION:±1%
transfer response:±4% 100% load
waveform : sine wave THD&lt;3% 0-100% LINEAR LOAD
OVERLOAD CAPACITY:120-150% FOR 30s,&gt;150% AUTO.LEAP TO BYPASS
POWER FACTOR:0.8-1,… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:4.8KW
INPUT VOLTAGE:1 PHASE 220VAC±25% 3 phase:380VAC±25%
INPUT FREQUENCY:50 OR 60HZ±5%
output voltage:220VAC±5% ADJUSTIBLE
OUTPUT FREQUENCY:50HZ±0.5% FREE RUNNING
VOLTAGE REGULATION:±1%
transfer response:±4% 100% load
waveform : sine wave THD&amp;lt;3% 0-100% LINEAR LOAD
OVERLOAD CAPACITY:120-150% FOR 30s,&amp;gt;150% AUTO.LEAP TO BYPASS
POWER FACTOR:… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:3.2KW
INPUT VOLTAGE:1 PHASE 220VAC±25% 3 phase:380VAC±25%
INPUT FREQUENCY:50 OR 60HZ±5%
output voltage:220VAC±5% ADJUSTIBLE
OUTPUT FREQUENCY:50HZ±0.5% FREE RUNNING
VOLTAGE REGULATION:±1%
transfer response:±4% 100% load
waveform : sine wave THD&lt;3% 0-100% LINEAR LOAD
OVERLOAD CAPACITY:120-150% FOR 30s,&gt;150% AUTO.LEAP TO BYPASS
POWER FACTOR:0.8-1,LA… |
| |
|
|  | | | Contact now | | | |
|
| CAPACITY:2.4KW
INPUT VOLTAGE:1 PHASE 220VAC±25% 3 phase:380VAC±25%
INPUT FREQUENCY:50 OR 60HZ±5%
output voltage:220VAC±5% ADJUSTIBLE
OUTPUT FREQUENCY:50HZ±0.5% FREE RUNNING
VOLTAGE REGULATION:±1%
transfer response:±4% 100% load
waveform : sine wave THD<3% 0-100% LINEAR LOAD
OVERLOAD CAPACITY:120-150% FOR 30s,>150% AUTO.LEAP TO BYPASS
POWER FACTOR:0.8-1,LAG
CREST RATIO:3… |
| |
| |